Health Canada · October 27, 2026

Siemens Shenzhen Magnetic Resonance Ltd Magnetom Free.Max Recall: The service pack NX VA60A-SP04 is a bug fix update

Affected product
Siemens Shenzhen Magnetic Resonance Ltd Magnetom Free.Max
Category
Health product
Hazard
The service pack NX VA60A-SP04 is a bug fix update (full installation) that solves/improves the following: Latest it security deliveries and increase in overall stability (syngo MR XA60A-SD12 content included) Installation of multiple SW delta packages now…
Check affected Siemens Shenzhen Magnetic Resonance Ltd Magnetom Free.Max identifiers →

Health Canada · October 27, 2026

Tj Trading Co. Inc. Dba Three Star Instant Aid Ovulation and Pregnancy Tests Recall: The manufacturer of the Instant Aid Pregnancy test

Affected product
Tj Trading Co. Inc. Dba Three Star Instant Aid Ovulation and Pregnancy Tests
Category
Medical device recalls
Hazard
The manufacturer of the Instant Aid Pregnancy test and Instant Aid Ovulation Tester has identified that these devices were distributed for sale in Canada without the appropriate device licence authorization. These over-the-counter devices are intended for home…
Check affected Tj Trading Co. Inc. Dba Three Star Instant Aid Ovulation and Pregnancy Tests identifiers →

Health Canada · October 27, 2026

Bbluv Group Inc Echo Wireless Fetal Doppler With Earphones Recall: Certain terms and statements in the instruction

Affected product
Bbluv Group Inc Echo Wireless Fetal Doppler With Earphones
Category
Health product
Hazard
Certain terms and statements in the instruction manual caused confusion regarding the nature of the product and its intended use. As a result, changes were made to clarify the instructions, improve consumer understanding and ensure the product's safe and…
Check affected Bbluv Group Inc Echo Wireless Fetal Doppler With Earphones identifiers →

Health Canada · October 27, 2026

Siemens Healthcare GmbH Magnetom Systems Recall: The service pack NX VA60A-SP04 is a bug fix update

Affected product
Siemens Healthcare GmbH Magnetom Systems
Category
Health product
Hazard
The service pack NX VA60A-SP04 is a bug fix update (full installation) that solves/improves the following: Latest it security deliveries and increase in overall stability (syngo MR XA60A-SD12 content included) Installation of multiple SW delta packages now…
Check affected Siemens Healthcare GmbH Magnetom Systems identifiers →

Health Canada · October 26, 2026

Abbott Diabetes Care Ltd FreeStyle Libre 3 App Recall: Abbott has identified an important security update

Affected product
Abbott Diabetes Care Ltd FreeStyle Libre 3 App
Category
Health product
Hazard
Abbott has identified an important security update for the FreeStyle Libre 3 App. This software update is required to maintain security of the apps. Following the security update to the FreeStyle Libre 3 App (Android and iOS), the software update implemented…
Check affected Abbott Diabetes Care Ltd FreeStyle Libre 3 App identifiers →

Health Canada · October 21, 2026

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V Azurion 7 Systems Recall: Philips Azurion systems use solid-state drives

Affected product
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V Azurion 7 Systems
Category
Health product
Hazard
Philips Azurion systems use solid-state drives (SSDs) in various PCs to store the operating system and image data and to support system functionality. Philips has identified that, during certain repair or service actions, SSDs that are not specified in the…
Check affected PHILIPS MEDICAL SYSTEMS NEDERLAND B.V Azurion 7 Systems identifiers →

Health Canada · October 21, 2026

Keystone Industries FP3D™ Resins Recall: FP3D™ is a dual cure resin indicated for the 3D

Affected product
Keystone Industries FP3D™ Resins
Category
Health product
Hazard
FP3D™ is a dual cure resin indicated for the 3D printed fabrication of flexible partial dentures in dental laboratories. Each unit is supplied in a 10:1 resin cartridge containing part a resin and part b resin. FP3D™ resin bottles may have been mis-filled…
Check affected Keystone Industries FP3D™ Resins identifiers →

Health Canada · October 21, 2026

Lupin Pharma Canada Ltd Femyso Mifepristone 200mg / Misoprostol 200 mcg tablet Recall: Affected lot may contain two green Mifepristone

Affected product
Lupin Pharma Canada Ltd Femyso Mifepristone 200mg / Misoprostol 200 mcg tablet
Category
Health product
Hazard
Affected lot may contain two green Mifepristone cartons or two pink Misoprostol cartons instead of one of each.
Check affected Lupin Pharma Canada Ltd Femyso Mifepristone 200mg / Misoprostol 200 mcg tablet identifiers →

Health Canada · October 19, 2026

Midmark Corporation IQecg® Digital ECG Recall: Affected IQecg® plugin software may produce

Affected product
Midmark Corporation IQecg® Digital ECG
Category
Health product
Hazard
Affected IQecg® plugin software may produce incorrect ECG waveforms and inaccurate heart-rate calculations. Until corrected software is installed, users should manually assess the patient's heart rate before initiating therapeutic intervention and use the…
Check affected Midmark Corporation IQecg® Digital ECG identifiers →

Health Canada · October 16, 2026

Nico Corporation NICO Myriad™ 19x21.5 MHP Paediscope Recall: Stryker identified the Myriad Paediscope handpiece

Affected product
Nico Corporation NICO Myriad™ 19x21.5 MHP Paediscope
Category
Health product
Hazard
Stryker identified the Myriad Paediscope handpiece may not fit through the included adapter to connect the handpiece to the neuroendoscope. There are three complaints reported for this issue.
Check affected Nico Corporation NICO Myriad™ 19x21.5 MHP Paediscope identifiers →

Health Canada · October 15, 2026

INSTRUMENTATION LABORATORY CO HemosIL AcuStar HIT-IgG(PF4-H) Recall: A performance issue was identified with HemosIL

Affected product
INSTRUMENTATION LABORATORY CO HemosIL AcuStar HIT-IgG(PF4-H)
Category
Product recall
Hazard
A performance issue was identified with HemosIL AcuStar HIT-lgG(PF4-HL ) for the Lot B38062. This performance issue may result in a negative analytical bias and calibration-related failures. Therefore, the Lot B38062 is being recalled and removed from the…
Check affected INSTRUMENTATION LABORATORY CO HemosIL AcuStar HIT-IgG(PF4-H) identifiers →

Health Canada · October 14, 2026

PHILIPS MEDICAL SYSTEMS NEDERLAND Philips Allura Xper Systems Recall: Philips has identified a software issue that may

Affected product
PHILIPS MEDICAL SYSTEMS NEDERLAND Philips Allura Xper Systems
Category
Product recall
Hazard
Philips has identified a software issue that may cause the Flexvision software application to become unresponsive during clinical use. When this occurs, the FlexVision monitor may either: • turn blank and no longer display live images or other information…
Check affected PHILIPS MEDICAL SYSTEMS NEDERLAND Philips Allura Xper Systems identifiers →

Health Canada · October 14, 2026

Tracoe Medical GmbH Tracoe Experc Percut Dilation Tracheostomy Set Recall: Tracoe is issuing a Field Safety Notice as the

Affected product
Tracoe Medical GmbH Tracoe Experc Percut Dilation Tracheostomy Set
Category
Product recall
Hazard
Tracoe is issuing a Field Safety Notice as the application bears a very low risk that the silicone sleeve may detach from the guiding catheter when removing the insertion system of the tracheostomy tube. The sleeve may remain in the cannula and block it,…
Check affected Tracoe Medical GmbH Tracoe Experc Percut Dilation Tracheostomy Set identifiers →

Health Canada · October 14, 2026

MEDTRONIC INC CareLink™ SmartSync™ Device Manager Recall: An update within the Apple iPad Operating System

Affected product
MEDTRONIC INC CareLink™ SmartSync™ Device Manager
Category
Product recall
Hazard
An update within the Apple iPad Operating System (OS) may reduce Bluetooth disconnections between the Medtronic CareLink™ SmartSync™ (SmartSync) device manager software and its associated accessories. Bluetooth disconnections occur for a variety of reasons.…
Check affected MEDTRONIC INC CareLink™ SmartSync™ Device Manager identifiers →

Health Canada · October 8, 2026

Biomet Uk Limited Avantage Inserter Handles and Grippers Recall: It was identified while using the Avantage inserter

Affected product
Biomet Uk Limited Avantage Inserter Handles and Grippers
Category
Product recall
Hazard
It was identified while using the Avantage inserter handles and grippers during the implantation of the acetabular shell, that the acetabular shell may not consistently disengage from the gripper when the trigger is unlocked. As a result, the inserter handle…
Check affected Biomet Uk Limited Avantage Inserter Handles and Grippers identifiers →

Health Canada · October 7, 2026

Hu-Friedy Mfg. Co., LLC Perma-Sharp Sutures Recall: Perma-sharp sutures are manufactured for Hu-Friedy

Affected product
Hu-Friedy Mfg. Co., LLC Perma-Sharp Sutures
Category
Product recall
Hazard
Perma-sharp sutures are manufactured for Hu-Friedy by 2 manufacturers. 1. Surgical Specialties Corporation has cleared for the U.S. market & 2. Camark SA are authorized for the European Union, United Kingdom, Switzerland, & Israel. Products have same…
Check affected Hu-Friedy Mfg. Co., LLC Perma-Sharp Sutures identifiers →

Health Canada · October 7, 2026

W.L. Gore & Associates Inc GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive Recall: Gore has identified through quality control testing

Affected product
W.L. Gore & Associates Inc GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive
Category
Product recall
Hazard
Gore has identified through quality control testing that some VIABAHN® devices were processed using equipment that was functioning outside of the validated range. This could potentially result in an incorrect bonding location of the distal tip onto the…
Check affected W.L. Gore & Associates Inc GORE® VIABAHN® Endoprosthesis with PROPATEN Bioactive identifiers →

Health Canada · October 6, 2026

Medtronic Xomed Inc Fluoroplastic Vent Tube Recall: Vent tube devices across lot 0231048280 were

Affected product
Medtronic Xomed Inc Fluoroplastic Vent Tube
Category
Product recall
Hazard
Vent tube devices across lot 0231048280 were identified to have been released to customers without undergoing sterilization. the issue is currently understood to originate from manufacturing (load preparation) and represents a fault condition: the product does…
Check affected Medtronic Xomed Inc Fluoroplastic Vent Tube identifiers →

Health Canada · October 6, 2026

Oxynov, Inc FreeO2 Automated Oxygen Therapy Device Adult & Pediatric Recall: A battery reading error may occur when certain

Affected product
Oxynov, Inc FreeO2 Automated Oxygen Therapy Device Adult & Pediatric
Category
Product recall
Hazard
A battery reading error may occur when certain Freeo2 HW 1.2 devices are restarted following an upgrade from software version 1.2.X to 1.4.X. The error is immediately detectable, prevents the device from being returned to service and requires installation of a…
Check affected Oxynov, Inc FreeO2 Automated Oxygen Therapy Device Adult & Pediatric identifiers →

Health Canada · October 5, 2026

Philips Ultrasound Llc Lumify Ultrasound System Recall: Potential issues with the Lumify Diagnostic

Affected product
Philips Ultrasound Llc Lumify Ultrasound System
Category
Product recall
Hazard
Potential issues with the Lumify Diagnostic Ultrasound System which may prevent or delay scanning functionality: Due to a software issue, the Lumify application may not recognize a previously registered transducer and prompt for re-registration (outside of the…
Check affected Philips Ultrasound Llc Lumify Ultrasound System identifiers →

Health Canada · October 2, 2026

Medline Industries, Lp Medline Single Sterile C-Section Drapes W/Incise Recall: Medline Industries, LP is issuing a correction

Affected product
Medline Industries, Lp Medline Single Sterile C-Section Drapes W/Incise
Category
Product recall
Hazard
Medline Industries, LP is issuing a correction notice for specific lot numbers of the Medline single sterile C-section drapes w/incise due to customer reports of C-section drapes being difficult to remove from patients, leaving adhesive residue on the…
Check affected Medline Industries, Lp Medline Single Sterile C-Section Drapes W/Incise identifiers →

Health Canada · October 2, 2026

Abiomed Inc Automated Impella® Controllers (AIC) Recall: Abiomed has decided to initiate a voluntary medical

Affected product
Abiomed Inc Automated Impella® Controllers (AIC)
Category
Product recall
Hazard
Abiomed has decided to initiate a voluntary medical device recall (removal) for design changes that were previously implemented through the Abiomed field service process. Abiomed performed a retrospective review of Field Change Notices (FCN) and determined…
Check affected Abiomed Inc Automated Impella® Controllers (AIC) identifiers →

Health Canada · October 1, 2026

MEDTRONIC INC CareLink™ SmartSync™ Device Manager Recall: A complaint from the CareLink network reported a

Affected product
MEDTRONIC INC CareLink™ SmartSync™ Device Manager
Category
Product recall
Hazard
A complaint from the CareLink network reported a sudden decrease in the Remaining Longevity of a patient's Micra VR CIED from 3 years to 6 months following a remote transmission, which was later found to be incorrect. Analysis revealed a calculation issue in…
Check affected MEDTRONIC INC CareLink™ SmartSync™ Device Manager identifiers →

Health Canada · October 1, 2026

Medline Industries, Lp Medline Sterile Surgical Kits containing Medline C-Section Recall: A recall correction notice for Medline Sterile

Affected product
Medline Industries, Lp Medline Sterile Surgical Kits containing Medline C-Section
Category
Product recall
Hazard
A recall correction notice for Medline Sterile Surgical Kits containing Medline C-Section Drape w/Incise is being issued due to reports of the drapes being difficult to remove from patients, leaving adhesive residue on their skin. In these cases, patients may…
Check affected Medline Industries, Lp Medline Sterile Surgical Kits containing Medline C-Section identifiers →

Health Canada · September 28, 2026

MEDTRONIC INC OmniaSecure™ MRI SureScan™ Recall: Medtronic’s manufacturing quality processes

Affected product
MEDTRONIC INC OmniaSecure™ MRI SureScan™
Category
Product recall
Hazard
Medtronic’s manufacturing quality processes identified a subset of OmniaSecure™ (Model 3930M) defibrillation leads which may have undergone a specific manufacturing sequence that requires these leads to be retrieved for additional engineering evaluation. As of…
Check affected MEDTRONIC INC OmniaSecure™ MRI SureScan™ identifiers →

Health Canada · September 25, 2026

Ethicon LLC PERMA-HAND™ Silk Suture Recall: Ethicon determined that PERMA-HAND™ Silk Suture

Affected product
Ethicon LLC PERMA-HAND™ Silk Suture
Category
Product recall
Hazard
Ethicon determined that PERMA-HAND™ Silk Suture subject to this recall (removal) was incorrectly manufactured with an alcohol-based tubing fluid in the primary packaging. This tubing fluid is an isopropyl alcohol (IPA), diethylaminoethanol (DEAE), and sodium…
Check affected Ethicon LLC PERMA-HAND™ Silk Suture identifiers →

Health Canada · September 25, 2026

ABBOTT MEDICAL Amplatzer™ Amulet™ Left Atrial Appendage Occluder Recall: The current Amulet™ IFU contains a contraindication

Affected product
ABBOTT MEDICAL Amplatzer™ Amulet™ Left Atrial Appendage Occluder
Category
Product recall
Hazard
The current Amulet™ IFU contains a contraindication against use "where placement of the device would interfere with any intracardiac or intravascular structures." Abbott is updating this contraindication to specifically identify the pulmonary artery as one of…