Sysmex Corporation Automated Blood Coagulation Analyzers Recall: In October 2026, the legal manufacturer Sysmex

Sysmex Corporation Automated Blood Coagulation Analyzers recall in Canada: In October 2026, the legal manufacturer Sysmex notified Siemens. Check models and the official notice.

CountryCanadaPublishedNovember 6, 2026Last updatedNovember 6, 2026Official source last checkedNovember 6, 2026 at 7:00 PM UTC

CHECK THE ITEM YOU OWN

Is your product affected?

Brand
Sysmex Corporation
Product
Automated Blood Coagulation Analyzers
Manufacturer
See official notice
Model number
BN343315, CL971029, AX801645, CV339763

The barcode may identify the product type, while the recall may apply only to certain lots, dates or variants. Check all identifiers listed in the official recall.

Why this product was recalled

In October 2026, the legal manufacturer Sysmex notified Siemens Healthineers of an urgent field safety notice for the analyzer CN series systems. Sysmex identified that deposits may accumulate on the sample arm B probe of the CN-series analyzers. The deposits may affect sample dispensing, potentially resulting in the delivery of a lower sample volume to the reaction cuvette than defined, which and may cause falsely decreased results. Based on the manufacturer’s investigation, the accumulation of deposits occurred due to insufficient washing of the sample arm B probe independent from the assays used.

Hazard

In October 2026, the legal manufacturer Sysmex notified Siemens Healthineers of an urgent field safety notice for the analyzer CN series systems. Sysmex identified that deposits may accumulate on the sample arm B probe of the CN-series analyzers. The deposits may affect sample dispensing, potentially resulting in the delivery of a lower sample volume to the reaction cuvette than defined, which and may cause falsely decreased results. Based on the manufacturer’s investigation, the accumulation of deposits occurred due to insufficient washing of the sample arm B probe independent from the assays used.

What consumers should do

Contact the manufacturer if you require additional information.

Official recall notice

Automated Blood Coagulation Analyzers

Agency: Health Canada

Official publication date: November 6, 2026

Read the official CANADA_MEDICAL_DEVICES recall notice →