Siemens Healthineers AG Magnetom and Biograph One Systems Recall: A software issue has been identified in syngo.via MR
Siemens Healthineers AG Magnetom and Biograph One Systems recall in Canada: A software issue has been identified in syngo.via MR Cardiac. Check models and the official notice.
CHECK THE ITEM YOU OWN
Is your product affected?
- Product
- Siemens Healthineers AG Magnetom and Biograph One Systems
- Manufacturer
- See official notice
- Model number
- 11291455, 11410482, 11851911, 11344916, 11689172, 11410481, 11060815, 11689652
The barcode may identify the product type, while the recall may apply only to certain lots, dates or variants. Check all identifiers listed in the official recall.
Why this product was recalled
A software issue has been identified in syngo.via MR Cardiac Analysis MR Flow Quantification affecting the evaluation of retrospectively gated 2D cardiac flow data. The algorithm does not correctly represent the final phase of the cardiac cycle. The evaluation stops at the last trigger time point (TT point), which marks the beginning of the final cardiac phase, instead of accounting for the complete duration of that phase until the end of the cardiac cycle. The final repetition-time interval (TR) is not included in the calculation (“TR missing”). This results in systematic truncation of the cardiac cycle and incomplete loop closure. Consequently, flow quantification parameters (e.g., Forward volume, Avg.Flow/Min) are systematically underestimated. The impact is relevant for Beat Sensor-triggered flow data, for which the flow peak occurs in the very last acquired cardiac phases.
Hazard
A software issue has been identified in syngo.via MR Cardiac Analysis MR Flow Quantification affecting the evaluation of retrospectively gated 2D cardiac flow data. The algorithm does not correctly represent the final phase of the cardiac cycle. The evaluation stops at the last trigger time point (TT point), which marks the beginning of the final cardiac phase, instead of accounting for the complete duration of that phase until the end of the cardiac cycle. The final repetition-time interval (TR) is not included in the calculation (“TR missing”). This results in systematic truncation of the cardiac cycle and incomplete loop closure. Consequently, flow quantification parameters (e.g., Forward volume, Avg.Flow/Min) are systematically underestimated. The impact is relevant for Beat Sensor-triggered flow data, for which the flow peak occurs in the very last acquired cardiac phases.
What consumers should do
Contact the manufacturer if you require additional information.
Official recall notice
Siemens Healthineers AG Magnetom and Biograph One Systems
Agency: Health Canada
Official publication date: October 28, 2026