PHILIPS MEDICAL SYSTEMS NEDERLAND B.V Veradius Unity and BV Pulsera Mobile C-Arm Recall: Air bubbles may develop in the monoblock oil when

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V Veradius Unity and BV Pulsera Mobile C-Arm recall in Canada: Air bubbles may develop in the monoblock. Check models and the official notice.

CountryCanadaPublishedSeptember 9, 2026Last updatedSeptember 9, 2026Official source last checkedOctober 18, 2026 at 10:11 PM UTC

CHECK THE ITEM YOU OWN

Is your product affected?

Brand
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Product
Veradius Unity and BV Pulsera Mobile C-Arm System-9in. and 12in. Versions
Manufacturer
See official notice
Model number
718132, 718095

The barcode may identify the product type, while the recall may apply only to certain lots, dates or variants. Check all identifiers listed in the official recall.

Why this product was recalled

Air bubbles may develop in the monoblock oil when there is a prolonged period between manufacture and installation, for example due to storage, transportation, or other pre-installation holding time. During a clinical procedure, when the user activates X-ray imaging, if an air bubble becomes trapped in the high-voltage area of the monoblock, there could be an internal electrical discharge (flashover) resulting in X-rays not being generated and consequently no image being displayed on the examination monitor. When this situation occurs, the system displays an error message indicating that the X-ray generator is not available. In some cases, restarting the system (which takes approximately 5 minutes) may restore X-ray generation. Philips' investigation indicates that this issue may occur during the early period of system use following a prolonged period between manufacture and installation. Based on the investigation, potentially affected systems have been identified as those for which more than 300 days elapsed between manufacture and installation and fewer than 250 days have elapsed since installation with continued system use, the monoblock oil temperature increases, allowing storage-related air bubbles to gradually dissipate over time.

Hazard

Air bubbles may develop in the monoblock oil when there is a prolonged period between manufacture and installation, for example due to storage, transportation, or other pre-installation holding time. During a clinical procedure, when the user activates X-ray imaging, if an air bubble becomes trapped in the high-voltage area of the monoblock, there could be an internal electrical discharge (flashover) resulting in X-rays not being generated and consequently no image being displayed on the examination monitor. When this situation occurs, the system displays an error message indicating that the X-ray generator is not available. In some cases, restarting the system (which takes approximately 5 minutes) may restore X-ray generation. Philips' investigation indicates that this issue may occur during the early period of system use following a prolonged period between manufacture and installation. Based on the investigation, potentially affected systems have been identified as those for which more than 300 days elapsed between manufacture and installation and fewer than 250 days have elapsed since installation with continued system use, the monoblock oil temperature increases, allowing storage-related air bubbles to gradually dissipate over time.

What consumers should do

Contact the manufacturer if you require additional information.

Official recall notice

Veradius Unity and BV Pulsera Mobile C-Arm System-9in. and 12in. Versions

Agency: Health Canada

Official publication date: September 9, 2026

Read the official CANADA_MEDICAL_DEVICES recall notice →